PFC MS – Medium Voltage Compensation
Optimizing network capacity: The highly exciting form of compensation!

Capacitors and compensation

Reactive power compensation

Detuned compensation

Compensation in station buildings

Active medium-voltage compensation

Filter circuit system
Save costs and use grids more efficiently with compensation systems!

Tailor-made solutions – individually tailored to your network requirements
Turnkey processing – complete project support for smooth integration
Made in Germany – proven quality with worldwide installation
Wide range of applications – Nominal voltages from 1 kV to 36 kV
Fixed capacitors CD.. and individual compensation

For small compensation powers (up to 1500 kvar), the batteries are preferably constructed from three-phase capacitors; for larger powers, the batteries are constructed from single-phase capacitors.
Functions
- Reactive power compensation
- Robust design
- Optimal natural cooling
- Low-loss all-film technology
- Small power with pressure switch
- High performance with asymmetry monitoring
- Hot-dip galvanized and painted hoods
- Optional inrush current limiting reactors
Technical data
- Nominal voltage 1..24 kV
- Rated power 50..9900 kVar
- Protection class IP00, IP54
Areas of application
- Transformer compensation
- Motor compensation
- Networks with low harmonic load
Reactive power compensation

Typical areas of application are: fixed motor compensation, fixed transformer compensation or central compensation in networks with harmonic load.
Functions
- Reactive power compensation
- Harmonic reduction
- HV fuses including fuse monitoring
- LINR or filter circuit choke
- Switch position indicator for circuit breakers/earthing switches
- Discharge time monitoring
- Indicator lights
- Emergency stop switch
- Single line on the front
- Door monitoring
- Separate low voltage
- Vacuum contactor
- Reactive power controller
Technical data
- Nominal voltage 1..15 kV
- Rated power 50..2500 kVar
- Choke 7%, others on request
- Protection class IP21, IP4xD
Areas of application
- Compensation in the interior
- Regulated reactive power compensation
- Networks with harmonic load
- Customer solutions
Detuned compensation

The SCOMP series systems are tested for arc fault resistance in accordance with Pehla Guideline 4. SCOMP compensation systems are available as control systems and as fixed compensation systems.
Functions
- Reactive power compensation
- Harmonic reduction
- Arc fault tested 25 kA/1s according to IEC 60298 1990 IAC test
- Up to 6 compensation levels (total max. 12 Mvar)
- Encapsulation of the individual stages
- 2 mm thick double walls and doors
- Indicator lights
- Temperature, asymmetry, door and pressure relief flap monitoring
- Variety of expansion and extension options
- Network analyzer with various communication interfaces
- Door lock
Technical data
- Nominal voltage 1..12 kV
- Rated power 50..2500 kVar
- Choke 7%, others on request
- Protection class IP41D
- Separate choke field
Areas of application
- Compensation with increased safety requirements
- Regulated reactive power compensation
- Networks with harmonic load
- Customer solutions
Compensation in station buildings

These systems are used in wind farms and PV parks as well as in the industrial sector.
Functions
- Reactive power compensation
- Harmonic reduction
- Ready-to-connect complete system
- A transport unit
- Construction as a container or concrete station
Technical data
- Nominal voltage 1..20 kV
- Rated power 150..7000 kVar
- Choke 5.67 %, 7%, others on request
- Protection class IP34D
Areas of application
- Compensation for outdoor installation
- Wind farms, solar parks
- Large-scale industry
- Harmonic filter
- Networks with harmonic load
- Customer solutions
Active medium-voltage compensation

Supplied as a weatherproof and climate-controlled, self-standing container solution or in a concrete station.
Functions
- Dynamic reactive power compensation
- Inductive / capacitive compensation
- Harmonic reduction
- Flicker reduction
- Ready-to-connect complete system
- A transport unit
- Construction as a container
Technical data
- Nominal voltage 1..20 kV
- Rated power 250..7500 kVar
- Protection class IP34D
Areas of application
- Compensation for outdoor installation
- Wind farms, solar parks
- Large-scale industry
- Energy supply
- Networks with harmonic load
- Customer solutions
Filter circuit systems

The systems are supplied in indoor and outdoor versions.
Functions
- Harmonic filtering
- Resonance damping
- TF lock
- Inductive compensation
- Ideal for high power requirements > 5 Mvar
- IP00 for indoor and outdoor use
- Air core/iron core chokes
- Asymmetry monitoring
- Optional damping resistor
- Optional phase current transformer
- Optional system visualization & DMC controller
Technical data
- Nominal voltage 1..36 kV
- Rated power 250..70,000 kVar
- Choke 7%, others on request
- Protection class IP00
Areas of application
- Compensation for outdoor/indoor installation
- Wind farms, solar parks
- Large-scale industry
- Networks with high harmonic load
- Customer solutions